This EPA, Region 4, document, SESDGUID-101-R1, Design and Installation of Monitoring Wells, replaces SESDPROC-101-R0, is an updated report describing the general and specific procedures, methods and considerations to be used and observed when designing and installing permanent and temporary groundwater monitoring wells to be used for collection of groundwater samples.
1.2 Scope/Application
The procedures contained in this document are to be used by field personnel when designing, constructing and installing groundwater monitoring wells. On the occasion that SESD field personnel determine that any of the procedures described in this section are either inappropriate, inadequate or impractical and that another procedure must be used for any aspect of the design, construction and/or installation of a groundwater monitoring well, the variant procedure will be documented in the field log book, along with a description of the circumstances requiring its use. Mention of trade names or commercial products does not constitute endorsement or recommendation for use.
1.3 Documentation/Verification
This procedure was prepared by persons deemed technically competent by SESD management, based on their knowledge, skills and abilities and has been tested in practice and reviewed in print by a subject matter expert. The official copy of this procedure resides on the SESD local area network (LAN). The Document Control Coordinator is responsible for ensuring the most recent version of the procedure is placed on the LAN and for maintaining records of review conducted prior to its issuance.
1.4 References
1.5 General Precautions
1.5.1 Safety
Proper safety precautions must be observed when constructing and installing groundwater monitoring wells. Refer to the SESD Safety, Health and Environmental Management Program Procedures and Policy (SHEMP) Manual (Most Recent Version) and any pertinent site-specific Health and Safety Plans
(HASPs) for guidelines on safety precautions. These guidelines should be used to complement the judgment of an experienced professional. When using this procedure, minimize exposure to potential health hazards through the use of protective clothing, eye wear and gloves. Address chemicals that pose specific toxicity or safety concerns and follow any other relevant requirements, as appropriate. Section 2.6, Safety Procedures for Drilling Activities, contains detailed and specific safety guidelines that must be followed by Branch personnel when conducting activities related to monitoring well construction and installation.
1.5.2 Procedural Precautions
The following precautions should be considered when constructing and installing groundwater monitoring wells:
• Special care must be taken to minimize or prevent inadvertent crosscontamination between borehole locations. Equipment, tools and well materials must be cleaned and/or decontaminated according to procedures found in SESD Operating Procedure for Field Equipment Cleaning and Decontamination (SESDPROC-205).
• All field activities are documented in a bound logbook according to the procedures found in SESD Operating Procedure for Logbooks (SESDPROC-010).
Read on .....